Field Service Ver. 1.0 Aug. 2005
MODE
Bit:
021
Bit
Feature
4
Call hold guard timer
3
2
Display symbol rate.
1
Observe EQM:
Check modem & line sta-
tuses
0
Observe probing informa-
tion:
Check modem & line sta-
tuses
MODE
Bit:
022
Bit
Feature
2
FAX memory nearly full to
its capacity.
1
Restrict parameters of
memory stored TX.
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500
Factory setting bit
7 6 5 4
3 2 1 0
0 0 0 0
1 0 0 0
Logic
0
1
Bit 4-3:
00
01
10
11
No
Yes
No
Yes
No
Yes
Factory setting bit
7 6 5 4
3 2 1 0
0 0 0 0
0 0 1 0
Logic
0
1
256 KB
512 KB
No
Yes
11. Soft Switch List
HEX:08
Description
1 hr
10 hr
24 hr
72 hr
Symbol rates are 2400/2743/2800/3000/
3200/3429.
Rate of 2743 is not actually used.
Do not change the set value.
Do not change the set value.
HEX:02
Description
"Memory nearly full" means that unused
memory becomes less than a specified
capacity.
This soft switch specifies threshold
capacity.
If "Yes" is selected, then all relay trans-
missions will proceed with A4 size when
function of remote side is unknown (not
learned/full dialing).
For learned destination without size of
16×15.4, TX will be done with 8×7.7.
65