Field Service Ver. 1.0 Aug. 2005
9.3.3

Staple Unit Misfeed

A. Detection Timing
Type
Staple Unit misfeed
detection
B. Action
Staple Unit 1
Staple Unit 2
Step
1
Initial check items
2
Drive Coupling Section check
3
I/O Check
4
Change Staple Unit 1
5
Change Staple Unit 2
6
Change PWB-C SK
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500
The Staple Home Position Sensor in the Staple Unit is not blocked even
after the set period of time has elapsed after the Staple Motor rotates for-
ward, and then the Staple Motor rotates backward, and the Staple Home
Position Sensor in the Staple Unit is blocked within the set period of time.
Relevant Electrical Parts
Action
Description
Main Control Board (PWB-C SK)
WIRING DIAGRAM
Control Signal
-
-
-
-
-
-
9. Jam Display
Location
(Electrical Component)
-
-
-
-
-
-