8. Trouble code
8.3
Solution
8.3.1
C0001: LCT communication error
Main Control Board (PWB-C1 LCT)
Step
1
Turn the main unit off, then on again.
2
PWB-C1 LCT replacement
8.3.2
C0209: LCT Elevator Motor Failure
Elevator Motor (M5-LCT)
Elevator Motor Pulse Sensor (PC10-LCT)
Step
Check the motor and sensor connectors
1
for proper connection, and correct as
necessary.
Check the connector of motor for proper
2
drive coupling, and correct as neces-
sary.
3
PC10-LCT sensor check
4
M5-LCT operation check
5
PWB-H LCT replacement
6
PWB-C1 LCT replacement
32
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500
Relevant electrical parts
Action
Relevant electrical parts
Action
PWB-C1 LCT PJ2H<A> LCT-5 (ON)
PWB-C1 LCT PJ2H<B> LCT-6 to 7
Field Service Ver. 1.0 Aug. 2005
WIRING DIAGRAM
Control signal
-
-
Interface Board (PWB-H LCT)
Main Control Board (PWB-C1 LCT)
WIRING DIAGRAM
Control signal
-
-
-
-
Location
(Electrical com-
ponents)
-
-
Location
(Electrical com-
ponents)
-
-
PC-402 G-5
PC-402 G-6
-
-