Field Service Ver. 1.0 Aug. 2005
7.3.22

CCD Unit

A. Replacing Procedure
1. Remove the IR Upper Left Cover.
49
2. Remove the Front Holding Bracket.
49
3. Remove the Original Glass.
49
[2]
[1]
[4]
[3]
[7]
B. Installation Adjustment to be Made when CCD Unit is Replaced
NOTE
• Make this adjustment only when the CCD Unit has been replaced with a new one.
• Before attempting to make this adjustment, make sure that registration and erase
adjustments for the printer have been completed.
• Do not loosen or remove the screws shown below.
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500
4. Remove six screws [1] and the CCD
[1]
Unit Cover [2].
[1]
4040F2C675DA
5. Move the Exposure Unit, remove the
[5]
wiring saddle [3], and disconnect the
connector [4].
6. Remove two screws [5] and two flat
[6]
springs [6]. Then, remove the CCD
Unit [7].
NOTE
When the CCD Unit has been replaced
4040F2C676DA
with a new one, make the installation
adjustment that must be made when
the CCD Unit is replaced.
65
4030D601AA
7. Other
65