11. Soft Switch List
MODE
Bit:
198
Bit
Feature
7
TX forwarding to adminis-
trator <*>
6
TX forwarding of scanner
function to administrator
<*>
5
Result report TX forward-
ing to administrator
4
MODE
212 (PSTN1)
232 (PSTN2)
Bit
Feature
7
Select DP make rate.
6
MODE
Bit:
249
Bit
Feature
7
Specify the ringing count
of auto receiving call
6
(PSTN2) <*>
5
4
3
NOTE
• The features with (*) are settable by users. <*>: Soft switch setting
• Some machines cannot receive calls.
Care must be taken when you set the ringing count to 10 or more.
• For PSTN1, refer to MODE 019.
98
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500
Factory setting bit
7 6 5 4
3 2 1 0
1 1 0 1
0 0 0 0
Logic
0
No
Yes
No
Yes
Bit 5-4:
00
01
10
11
Factory setting bit
Bit:
7 6 5 4
0 0 0 0
Logic
0
Bit 7-6:
00
01
Others
Factory setting bit
7 6 5 4
3 2 1 0
0 0 0 0
1 0 0 0
Logic
0
Bit 7-3:
00000
00001
10100
Others
Field Service Ver. 1.0 Aug. 2005
HEX:D0
Description
1
Not output
Output for
incomplete TX
Always output
Not available
3 2 1 0
HEX:40 (For U.S.)
0 0 0 0
HEX:00 (For Europe)
Description
1
33 %
Specify the DP signal
make ratio.
40 %
Not available
HEX:08
Description
1
0
Specify the PSTN2 ring-
ing detection count. The
1
ringing count is the num-
|
ber of rings until the
20
machine automatically
starts receiving a call.
Not available