Field Service Ver. 1.0 Aug. 2005
4.6.3

Replacement of the Photo Conductor Unit

1. Select Tech. Rep. Mode → [Counter] → [Special Parts Counter] → [PC Life].
2. Press the Clear key to clear the counter value.
3. Turn OFF the main power switch.
NOTE
• Clear the PC Life counter before removing the IU.
• After clearing the PC Life counter, be sure to turn OFF the main power switch.
[3]
[2]
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500
4. Open the Right Door.
[1]
5. Remove the IU [1].
4040F2C555DA
[2]
6. Remove four screws (silver) [2] and
disassemble the Photo Conductor
Unit [3] and the Developing Unit [4].
7. Replace the Photo Conductor Unit
[3].
8. To reinstall, reverse the order of
removal.
[4]
NOTE
4040F2C556DA
• Replace the Toner Filter (Develop-
ing Unit) with a new one at the same
time.
4. Periodical check