11.3 List Of Soft Switches - Konica Minolta bizhub 250 Service Manual

Mfp
Hide thumbs Also See for bizhub 250:
Table of Contents

Advertisement

Field Service Ver. 1.0 Aug. 2005

11.3 List of Soft Switches

NOTE
• If no bit settings are given in the soft switch list that follows, the factory settings
for those particular bits are fixed and should never be changed.
: Default settings of U.S.
: Default settings of Europe
: Default settings are common
MODE
Bit:
000
Bit
Feature
7
Specifies whether TX
markers are return to ON
or OFF after completing
operations. <*>
6
Select position of TX
markers. <*>
5
Specifies whether print-
ing TSI on transmitted
document is returned to
ON or OFF after complet-
ing operations. *
4
Select position of TSI. *
3
Specifies whether con-
firming communication
password at TX is
returned to ON or OFF
after completing opera-
tions. <*>
2
Confirm communication
password at RX. <*>
1
Specifies which TX
method is returned to ON,
memory-stored TX or
nonstorage TX, after com-
pleting operations. *
NOTE
• The features with (*) are settable by users. *: Screen setting <*>: Soft switch setting
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500
Factory setting bit
7 6 5 4
3 2 1 0
0 0 1 1
0 0 0 0
Logic
0
1
OFF
Yes
Top &
bottom of
bottom
doc.
of doc.
No
Yes
Outside
Outside
doc.
doc.
No
Yes
No
Yes
Memory-
Non-
stored
stored
11. Soft Switch List
HEX:30
Description
Memory-stored TX
includes quick
memory TX.
51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub 200Bizhub 350