Replacing The Separation Roller Assy (Tray 1) - Konica Minolta bizhub 500 Service Manual

Hide thumbs Also See for bizhub 500:
Table of Contents

Advertisement

3. PERIODIC CHECK
3.12.2

Replacing the separation roller assy (tray 1)

A. Periodically replaced part/cycle
Separation roller assy
*1
500/420
*2
360
B. Procedure
[2]
[5]
[4]
52
1
: Every 750,000 prints (Actual replacement cycle: Every 300,000 prints) *1
: Every 675,000 prints (Actual replacement cycle: Every 300,000 prints) *2
[1]
[3]
50gaf2c117na
[1]
[2]
[1]
[3]
50gaf2c118na
Confidential – for internal use only, do not distribute
Field Service Ver.2.0 Jan. 2007
1.
Remove the tray 1.
(See P.163)
2.
Remove the paper feed unit /1.
(See P.47)
3.
Remove the separation roller unit /1.
(See P.47)
4.
Remove the 2 screws [1] and then remove the
separation roller mounting plate assy [2].
Note
• When installing the separation roller mount-
ing plate assy, be sure to fasten it with screws
while pressing it in the arrow-marked direc-
tion [3].
5.
Remove the 2 C-rings [1] and pull out the shaft [2].
6.
Remove the separation roller mounting plate [3].
Note
• When removing the separation roller mount-
ing plate, be careful that the spring [4] does
not get lost since it is apt to come off.
• When installing the separation roller mount-
ing plate, be sure to install it so that it comes
under the projection [5].

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub 360Bizhub 420

Table of Contents