3. Periodical check
[8]
3.5.4
Replacing the Bypass Tray Separation Roller Assy
[2]
[4]
20
6. Remove the Bypass Tray Feed Roller
[8].
7. To reinstall, reverse the order of
removal.
8. Select [Service Mode] → [Counter]
→ [Life] and clear the count of
[Manual Tray].
NOTE
• Replace the Bypass Tray Feed
Roller and the Bypass Separation
Roller Assy at the same time.
4038F2C008DB
1. Remove the Multi Bypass Unit.
See P.113
2. Remove the Screw [1], and remove
the Ground terminal [2].
[1]
4038F2C009DA
3. Remove the Screw [3], and remove
the Bypass Paper Separation Roller
Assy [4].
[3]
4038F2C010DA
Field Service Ver. 3.0 Aug. 2006