8. Trouble code
8.3.5

C0213: LCT Shift Gate Operation Failure

Shift Gate Home Position Sensor (PC14-LCT)
Shift Gate Motor (M3-LCT)
Step
Check the motor and sensor connectors
1
for proper connection, and correct as
necessary.
Check the connector of motor for proper
2
drive coupling, and correct as neces-
sary.
3
PC14-LCT sensor check
4
M3-LCT operation check
5
PWB-C1 LCT replacement
8.3.6

C0214: LCT Shift Failure

Shift Motor Pulse Sensor (PC8-LCT)
Shifter Return Position Sensor (PC11-LCT)
Shifter Home Position Sensor (PC12-LCT)
Step
Check the sensor connectors for proper
1
connection, and correct as necessary.
2
PC8-LCT sensor check
3
PC11-LCT sensor check
4
PC12-LCT sensor check
5
PWB-C1 LCT replacement
34
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500
Relevant electrical parts
Action
PWB-C1 LCT PJ2H<B> LCT-1 (ON)
PWB-C1 LCT PJ2H<B> LCT-2 to 3
Relevant electrical parts
Action
PWB-C1 LCT PJ2H<A> LCT-3 (ON)
PWB-C1 LCT PJ2H<A> LCT-7 (ON)
PWB-C1 LCT PJ2H<A> LCT-8 (ON)
Field Service Ver. 1.0 Aug. 2005
Main Control Board (PWB-C1 LCT)
WIRING DIAGRAM
Control signal
-
-
-
Main Control Board (PWB-C1 LCT)
WIRING DIAGRAM
Control signal
-
-
Location
(Electrical com-
ponents)
-
-
PC-402 G-6
PC-402 G-6
-
Location
(Electrical com-
ponents)
-
PC-402 G-5
PC-402 G-4
PC-402 G-4
-