NEC Univerge SV8100 Features And Specifications Manual page 161

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Program Name
Number
80-03-05
DTMF Tone Receiver Setup –
Forward Twist Level
80-03-06
DTMF Tone Receiver Setup –
Backwards Twist Level
80-03-07
DTMF Tone Receiver Setup – ON
Detect Time
80-03-08
DTMF Tone Receiver Setup –
OFF Detect Time
Automatic Route Selection
Description/Comments
Define the forward twist level for
DTMF Tone Receiver.
Define the backwards twist level
for DTMF Tone Receiver.
Define the On detection time for
DTMF Tone Receiver.
Define the Off detection time for
DTMF Tone Receiver.
Assigned Data
1
0~9
(1dB~10dB)
default:
Type 1 = 5 (6dBm)
Type 2 = 5 (6dBm)
Type 3 = 5 (6dBm)
Type 4 = 5 (6dBm)
Type 5 = 5 (6dBm)
0~9
(1dB~10dB)
default:
Type 1 = 0 (1dBm)
Type 2 = 0 (1dBm)
Type 3 = 0 (1dBm)
Type 4 = 0 (1dBm)
Type 5 = 0 (1dBm)
1~255
(15+ 15ms~3825ms)
default:
Type 1 = 1 (30ms)
Type 2 = 1 (30ms)
Type 3 = 1 (30ms)
Type 4 = 1 (30ms)
Type 5 = 1 (30ms)
1~255
(15+ 15ms~3825ms)
default:
Type 1 = 1 (30ms)
Type 2 = 1 (30ms)
Type 3 = 1 (30ms)
Type 4 = 1 (30ms)
Type 5 = 1 (30ms)
Issue 12.0