NEC Univerge SV8100 Features And Specifications Manual page 116

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 12.0
Program
Program Name
Number
15-11-01
Virtual Extension Delayed Ring
Assignment
20-04-03
System Options for Virtual
Extensions – CAR/SIE/Virtual
Extension Delay Interval
20-06-01
Class of Service for Extensions
20-13-06
Class of Service Options
(Supplementary Service) –
Automatic Off-Hook Signaling
(Automatic Override)
20-13-33
Class of Service Options
(Supplementary Service) – ACD
Supervisor's Position
Enhancement
20-13-39
Class of Service Options
(Supplementary Service) – ACD
Queue Status Display
22-01-11
System Options for Incoming
Calls – VRS Waiting Message
Interval Time
30-01-01
DSS Console Operating Mode
30-05-04
DSS Console Lamp Table – ACD
Agent Busy
2 - 86
Description/Comments
Assign the delayed ringing options
for an extension Virtual Extension
or Virtual Extension Group Answer
keys (defined in Program 15-09).
You make an assignment for each
Night Service Mode. There are
256 Virtual Extension Ports.
CAR Keys/SIE Keys/Virtual
Extensions set for Delayed
Ringing (see Program 15-11) ring
the extension after this interval.
Assign a Class of Service (COS)
to an extension. There are 15
Classes of Service that can be
assigned. Assign eight entries,
one for each Night Service Mode.
Allows a busy extension to
Manually (0) or Automatically (1)
receive off-hook signals.
Set this option to On for the
operator to use service codes in
Program 11-13-10~11-13-13.
Turn Off or On the ACD Queue
Status Display for an extension
Class of Service. Any extension,
which has this option enabled,
also hears the queue alarm.
Setup the sending duration time of
the Auto – Attendant & Queuing.
The message is repeatedly sent
out during the specified time.
Set the mode of the system DSS
consoles. The entry for this option
applies to all the system DSS
consoles.
Define the LED patterns for
functions on the DSS consoles.
The entry for this option applies to
all the system DSS consoles.
UNIVERGE SV8100
Assigned Data
Day Night/Mode: 1~8
Ringing:
0 = Immediate Ring
1 = Delayed Ring
(default = 0)
0~64800 (seconds)
(default = 10)
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1
0 = Off
1 = On
(default = 1 for COS
01~15)
0 = Off
1 = On
(default = 0 for COS
01~15)
0 = Off
1 = On
(default = 0 for COS
01~15)
0~64800 (seconds)
(default = 20)
0 = Business Mode
1 = Hotel Mode
2 = ACD Monitor Mode
3 = Business/ACD
Mode
(default = 0)
Lamp Pattern Data
0~7
[default = 7(on)]
Automatic Call Distribution (ACD)
Level
1
2
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents