APR/APA Hookflash Selection

General Description
Use this Memory Block to allow/deny Hookflash for Analog Port Adapter with Ringer
(AP(R)-R/APR-U) or Analog Port Adapter (AP(A)-R/APA-U) without ringer on a
Multiline Terminal.
Display
T e l P o r t
N o .
D a t a
( 0 1 ~ C O )
N o .
0 1 / 5 9 : H K
T I M E
Settings
Page 1
LK 1
LK 2
NO
YS
Programming Procedures
1 Go off-line.
E I
2 Press LK4 +
3 Press the corresponding CO/PBX line key to change the setting data option.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
I
~
to enter numeric data or Tel Port No.
D
– OR –
B
to go to next assigned Tel Port No.
B
A
+
B
B
+
C
G
+
4 Press
to write the data and display Memory Block 4-1 for next Tel Port No.
5 Program the next Tel Port No. or press
Related Programming
M.B. Number
Memory Block Name
1-1-02
Hookflash Time Selection
1-3-02
SLT Hookflash Signal Selection
4-39
APR Ring Mode Assignment
___________________________________________________________________________________
Programming Manual
S e t t i n g
T i t l e
D a t a
F L S H
N O
D I S P L A Y
LK 3
LK 4
to access the Memory Block.
t o enter A for Port Numbers 100~109
t o enter B for Port Numbers 110~119
t o enter C for Port Number 120
E
to go back on-line.
LK 5
LK 6
LK 7
Document Revison 1
CO/PBX Line Mode
4
Submode
Data No.
59
PC Programming
+AU
LK 8
The shaded
selection is the
default.
2 - 523