___________________________________________________________________________________
3-14

Tie Line Type Assignment

General Description
Use this Memory Block to assign the loop supervision to be used for each Trunk
associated with a Tie line.
Display
T i e / D I D
N o .
D a t a
N o .
( 0 1 ~ 6 4 )
0 1 / 1 4 : 2 N D
T I M E
Settings
LK 1
LK 2
2ND DIAL
IMMEDIATE
Programming Procedures
G
1 Go off-line.
2 Press LK3 +
3 Press the corresponding CO/PBX line key to change the loop supervision for CO/PBX No.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
I
~
to enter numeric data or CO/PBX No.
D
– OR –
G
to go to the next assigned CO/PBX No.
4 Press
to write the data and display the next Memory Block.
5 Program the next Memory Block or press
Related Programming
M.B. Number
Memory Block Name
3-92
Trunk (Installed, DP/DTMF) Selection
___________________________________________________________________________________
2 - 390
T i t l e
D I A L
D I S P L A Y
LK 3
LK 4
DELAY
WINK
A D
+
t o access the Memory Block.
E
LK 5
LK 6
LK 7
to go back on-line.
CO/PBX Line Mode
3
Submode
Data No.
14
PC Programming
+ALT
LK 8
The shaded
selection is the
default.