General Description
Use this Memory Block to specify the time after the incoming signal from another
system is detected before the acknowledge signal is sent out.
Display
C O / P B X
D a t a
N o .
N o .
( 0 1 ~ 6 4 )
0 1 / 1 9 : I N C
T I M E
Settings
Page 1 – Wink Start
LK 1
LK 2
00 (0 ms.)
01 (130 ms.) 02 (260 ms.) 03 (390 ms.) 04 (520 ms.) 05 (650 ms.) 06 (780 ms.) 07 (910 ms.)
Page 2
LK 1
LK 2
08 (1040
09 (1170
ms.)
ms.)
Page 1 – Delay
LK 1
LK 2
00 (0 ms.)
01 (30 ms.)
Page 2
LK 1
LK 2
08 (240 ms.) 09 (270 ms.) 10 (300 ms.) 11 (330 ms.) 12 (360 ms.) 13 (390 ms.) 14 (420 ms.) 15 (450 ms.)
Page 1 – COI
LK 1
LK 2
00 (50 ms.)
01 (100 ms.) 02 (150 ms.) 03 (200 ms.) 04 (250 ms.) 05 (300 ms.) 06 (350 ms.) 07 (400 ms.)
Page 2
LK 1
LK 2
08 (450 ms.) 09 (500 ms.) 10 (550 ms.) 11 (600 ms.) 12 (650 ms.) 13 (700 ms.) 14 (750 ms.) 15 (800 ms.)
Programming Procedures
G
1 Go off-line.
2 Press LK3 +
___________________________________________________________________________________
2 - 398
S e t t i n g
T i t l e
D a t a
0 3
| 1
D I S P L A Y
LK 3
LK 4
LK 3
LK 4
10 (1300
11 (1430
ms.)
ms.)
LK 3
LK 4
02 (60 ms.)
03 (90 ms.)
LK 3
LK 4
LK 3
LK 4
LK 3
LK 4
A I
+
to access the Memory Block.
P a g e
N o .
LK 5
LK 6
LK 5
LK 6
12 (1560
13 (1690
ms.)
ms.)
LK 5
LK 6
04 (120 ms.) 05 (150 ms.) 06 (180 ms.) 07 (210 ms.)
LK 5
LK 6
LK 5
LK 6
LK 5
LK 6
CO/PBX Line Mode
PC Programming
LK 7
LK 8
LK 7
LK 8
14 (1820
15 (1950
ms.)
ms.)
LK 7
LK 8
The shaded
selection is the
default for each
method.
LK 7
LK 8
LK 7
LK 8
LK 7
LK 8
Programming Manual
Elite IPK
3
Submode
Data No.
19
+BCT