Code Restriction Class Assignment When Lockout Is Set - NEC Electra Elite IPK Programing Manual

Hide thumbs Also See for Electra Elite IPK:
Table of Contents

Advertisement

Elite IPK
___________________________________________________________________________________
1-1-70
Code Restriction Class Assignment
When Lockout is Set
General Description
Use this Memory Block to assign the Code Restriction Class when a station user sets
the Station Outgoing Lockout or when the Attendant sets Attendant Station Outgoing
Lockout.
Display
D a t a
N o .
7 0 : R E S T
T I M E
Programming Procedures
1 Go off-line.
G K
2 Press LK1 + LK1 +
3 Used dial pad to enter class restriction.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
I
G
t o enter numeric data
~
4 Press
to write selected data and display the next Memory Block.
5 Program the next Memory Block or press
Related Programming
Refer to
Chapter 3 Advanced
When a station is locked out, the Code Restriction Class Assignment of this Memory Block is used instead of the
Code Restriction Class assigned in Memory Block 4-07 [Code Restriction Class Assignment (Day Mode)] or 4-08
[Code Restriction Class Assignment (Night Mode)].
___________________________________________________________________________________
Programming Manual
S e t t i n g
T i t l e
D a t a
C L A S S = 1 5
D I S P L A Y
to access the Memory Block.
E
to go back on-line.
Applications,
Section 1 Code Restriction on page
3-1.
Notes
Document Revision 1
System Mode
1
Submode
1
Data No.
70
PC Programming
+AC
Default Values
Class 15
2 - 81