External Ring Relay Pattern Selection - NEC Electra Elite IPK Programing Manual

Hide thumbs Also See for Electra Elite IPK:
Table of Contents

Advertisement

Document Revison 1
___________________________________________________________________________________
1-7-07

External Ring Relay Pattern Selection

General Description
Use this Memory Block to assign a distinctive ringing control/interval pattern to relay
circuits.
Display
D a t a
N o .
0 7 : E X T
T I M E
Settings
LK 1
LK 2
PT1
PT2
Programming Procedures
1 Go off-line.
K G
2 Press L1 + LK7 +
Press corresponding CO/PBX line key to change the data option.
3
G
Use dial pad keys 1~4 to specify external ring relay.
4 Press
to write the data.
5 Repeat Steps 3 and 4 for each of the four Ring Relays. The next Memory Block is displayed.
6 Program the next Memory Block or press
Related Programming
M.B. Number
Memory Block Name
1-2-00
Internal Paging Timeout Selection
External Speaker Connection Selection
1-7-02
ECR Relay to Tenant Assignment
2-08
An External Tone relay or the Night Chime relay must be assigned in Memory Block 2-08 (ECR Relay to Tenant
Assignment) before the tone is generated.
___________________________________________________________________________________
2 - 176
E x t
R i n g
R e l a y
S e t t i n g
T i t l e
( 1 ~ 4 )
D a t a
R I N G 1 = P T 3
D I S P L A Y
LK 3
LK 4
LK 5
PT5
PT3
PT4
to access the Memory Block.
E
to go back on-line.
LK 6
LK 7
PT6
PT7
(Continuous
Notes
Elite IPK
System Mode
1
Submode
7
Data No.
07
PC Programming
+BP
LK 8
The shaded
selection is the
default.
Memory Blocks

Hide quick links:

Advertisement

Table of Contents
loading