NEC Electra Elite IPK Programing Manual page 320

Hide thumbs Also See for Electra Elite IPK:
Table of Contents

Advertisement

Elite IPK
___________________________________________________________________________________
1-10-08 Call by Call Max Digit Assignment
General Description
Use this Memory Block to specify the maximum digits dialed for each Route Advance
Block (RAB). When the maximum digits are dialed, the PRT(1)-U( ) ETU sends
SETUP information to the ISDN Provider (Network).
Display
R A B
D a t a
0 1 ~ 3 2
N o .
0 1 / 0 8 : M D G T
T I M E
Programming Procedures
1 Go off-line.
J H
2 Press LK1 + LK10 +
3 Enter data using the dial pad.
Use the following to enter data:
J
L
and
K
D
I
~
to enter data
to select next RAB No.
Setting Data = 00 (No Limit)
G
4 Press
to write the data. The next Memory Block is displayed.
5 Program the next Memory Block or press
Related Programming
M.B. Number
Memory Block Name
3-03
Trunk-to-Trunk Group Assignment
1-1-30
Route Advance Block Assignment
1-1-46, 47, 48
Access Code (1-, 2-, or 3-Digit) Assignment
1-10-00
Call by Call Type of Network ID Assignment
1-10-01
Call by Call ID Plan Assignment
1-10-02
Call by Call Type of Number Assignment
1-10-03
Call by Call Numbering Plan ID Assignment
1-10-04
Call by Call Network ID Assignment
1-10-05
Call by Call Facility Coding Value Assignment (Service)
___________________________________________________________________________________
Programming Manual
S e t t i n g
T i t l e
D a t a
=
D I S P L A Y
to access the Memory Block.
to move the cursor
= 01~24 digits
E
0 0
to go back on-line.
Document Revision 1
System Mode
Submode
Data No.
PC Programming
Default Values
All RABs
00 (No Limit)
1
10
08
+AY
2 - 249

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents