General Description
Use this Memory Block to assign stations to one of four simplified call distribution
groups. A total of 32 stations can be assigned.
Display
D a t a
N o .
T i t l e
3 0 : S G
T I M E
Programming Procedures
1
Go off-line.
C K
2
Press LK1 + LK8 +
3
Use dial pad to enter Grp (1~4) and the Setting Data (station number) for each agent.
Use the following to enter data:
K
I
~
to enter digits
J
to move cursor left
L
to move cursor right
G
Setting Data = Maximum of 4 digits
4
Press
to write the data and select the next Agent No.
5
Repeat Steps 3 and 4 for each remaining Agent No. The next Memory Block is displayed.
6
Program next Memory Block or press