In the Alert Indications section of the Settings tab, you can select which events
trigger Simple Network Management Protocol (SNMP) traps. You can also
define multiple SNMP servers to which the Gateway sends the SNMP traps.
The Gateway supports traps in the SNMPv1 format.
Note
Procedure
In the Gateway interface, on the sidebar, click Gateway (if not already
1
selected).
Click the Settings tab.
2
Click Alert Indications.
3
In the Events section, select events in the Disabled events field and click
4
Add to select an event to monitor. Or, select an event in the Enabled
events field and click Remove to remove that event from monitoring.
Select the Send SNMP Traps check box to configure the IP address of
5
the SNMP server to which the Gateway sends SNMP trap notifications
of the events selected in the Enabled events field. You can configure up
to three different SNMP trap servers.
In the Trap server IP and Port fields, enter the IP address and port
6
number for each SNMP server to which you want the Gateway to send
SNMP trap notifications. To remove an SNMP server, set the SNMP
server IP address to 0.0.0.0 and click Upload.
Related Topics
Gateway Event Types
Trap Severity Enumeration
Configuring Gateway Settings
on page 102
on page 108
Configuring the SCOPIA Gateway