Initial Gateway Configuration
36
SCOPIA 400/1000 Gateway User Guide
Procedure
Connect the
1
supplied terminal
Connect the power cable.
2
Start the terminal emulation application on the PC.
3
Set the communication settings in the terminal emulation
4
application on the PC as follows:
Baud rate: 9600
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Turn on the power to the Gateway.
5
After the terminal emulator session starts, press the RST
6
button on the Gateway front panel to reset the module.
A log of the auto-boot events and a VxWorks banner scrolls
across the computer monitor.
When the Gateway is started for the first time, two VxWorks banners
Note
appear. The configuration option appears after the second banner.
When the message "Press any key to start configuration"
7
appears on the screen, press any key within 6 seconds.
The network configuration Main menu displays:
Press any Key To start configuration...
Main menu
Enter <N> to configure default network port values
Enter <P> to change the configuration software password
Enter <A> to display advanced configuration menu
Enter <Q> to quit configuration menu and start GW
If you do not press a key before the countdown ends, the device
Caution
continues its initialization and you can only configure the device by pressing
the RST button on the front panel.
cable to the PC terminal.