  • Page 1 SCOPIA 400 Platform Guide...
  • Page 2 Ltd. and a copy will be provided to you. RADVISION Unless otherwise indicated, registered trademarks are registered in the United States RADVISION and other territories. All registered trademarks recognized. For further information contact or your local distributor or reseller. RADVISION SCOPIA 400 Platform, October 2007 Publication 6 http://www.radvision.com...
  • Page 3: Table Of Contents

    ONTENTS About This Manual Related Documentation SCOPIA 400 Platform Chassis Overview About the SCOPIA 400 Platform About the SCOPIA 400 Chassis About the Rear Transition Module Viewing System Indicators System Power Indication System Alarm Indication System Fan Indication System Temperature Indication...
  • Page 4 Electrical Safety Grounding High Voltage Power Supply ESD Procedures Sicherheit Elektrische Sicherheit Erdung Hochspannung Netzteil ESD-Verfahren Warnhinweise Seguridad Seguridad Electrica Tierra Alto Voltage Abastecimiento de Electricidad Procedimientos ESD Securite Securite Electrique Mise a la Terre iv SCOPIA 400 Platform Guide...
  • Page 5 Haute Tension Alimentation Electrique Prevention des Decharges Electrostatiques Compliance and Certifications Safety Compliance FCC Part 15 Notice Telecom ACTA Customer Information Canadian Department of Communications Notice Environmental Compliance Contents v...
  • Page 6 SCOPIA 400 Platform Guide...
  • Page 7: Related Documentation

    ELATED The SCOPIA 400 platform documentation set is available on the RADVISION Utilities and Documentation CD and includes manuals and online helps. The OCUMENTATION manuals are available in PDF format.
  • Page 9: Scopia 400 Platform Chassis Overview

    The SCOPIA 400 platform consists of a number of embedded applications on blades that are inserted into the SCOPIA 400 chassis. BOUT THE The SCOPIA 400 chassis is 3.5" (2U) high and can mount in a 19-inch rack. The SCOPIA 400 chassis can accommodate a device blade in each of its four slots.
  • Page 10: About The Rear Transition Module

    You can also monitor chassis functions remotely via the web user interface Note of the MCU or Gateway installed in the top slot of the SCOPIA 400 chassis. If you install a SCOPIA Media and Video Processor in the top slot of the SCOPIA 400 chassis, monitoring via the web is not available.
  • Page 11: System Fan Indication

    When the platform initialization is complete, the LED indicators remain green. SCOPIA 400 The rear panel of the SCOPIA 400 chassis contains dual power supply units, each with a power switch, an AC mains power connector and a safety fuse. The HASSIS OWER two PSUs use current sharing to provide redundancy—if one PSU fails, the...
  • Page 12: Replacing A Power Supply Unit

    SCOPIA 400 Chassis Power Supply Figure 1-2 SCOPIA 400 Chassis Power Supply You can remove and replace each power supply unit, even while in operation EPLACING A OWER UPPLY (Hot Swap). The platform can continue to operate with a single PSU until the second PSU is replaced.
  • Page 13 SCOPIA 400 Chassis Power Supply Figure 1-4 Removing a Power Supply Unit Insert a new PSU, sliding it into the connectors inside the PSU slot. Press firmly on the new PSU to ensure that the connectors have engaged properly and that the outside of the PSU is in line with the chassis rear panel.
  • Page 14 SCOPIA 400 Chassis Power Supply SCOPIA 400 Platform Guide...
  • Page 15: Scopia 400 Platform Device Overview

    A video processing card dedicated to the SCOPIA MCU that can support 24 flat capacity video ports. MSP SP A Multimedia Streaming Proxy that enables streaming to mobile handsets from streaming servers and network cameras. SCOPIA 400 Platform Device Overview...
  • Page 16 Gateway [gw-N30] An Interworking Gateway enabling conversion between H.323 and SIP endpoints. The component of the RADVISION 3G system which supports SIP networks. Gateway [gw-P25/M SP] Holds two PRI interfaces per board for interfacing with 3G circuit switched cellular networks to which 3G-324M videophones are connected.
  • Page 17: Cable Connections And Pin-Outs

    ABLE ONNECTIONS AND OUTS This section describes the pin-to-pin and pin-out configurations of the connectors and cables of the SCOPIA 400 chassis, including the following topics: Unit RS-232 9-Pin Serial Port 9-Pin Serial Port Terminal Cable RJ-45 8-Pin IP Network Port...
  • Page 18: Unit Rs-232 9-Pin Serial Port

    Unit RS-232 9-Pin Serial Port RS-232 9-P Table 3-1 describes the SCOPIA 400 chassis RS-232 9-pin D-type serial port pin-out configuration. ERIAL Table 3-1 RS-232 9-pin D-Type Serial Port Pin-out Function Input Output ERIAL Table 3-2 describes the pin-to-pin configuration of the RS-232 terminal cable...
  • Page 19: 8-Pin Ip Network Port

    RJ-45 to DB-9 adapter cable used to connect a PC terminal to the RJ-45 serial port. This cable is DAPTER provided with the SCOPIA 400 chassis. ABLE Table 3-4 Pin-to-Pin Configuration of the RJ-45 to DB-9 Adapter Cable...
  • Page 20 Circuit Switch Network Port SCOPIA 400 Platform Guide...
  • Page 21: Technical Specifications Table

    ECHNICAL PECIFICATIONS This section provides technical specifications for the .SCOPIA 400 Chassis ECHNICAL PECIFICATIONS Table 4-1 SCOPIA 400 Chassis Technical Specifications ABLE Chassis Dimensions Height: 2U (3.5 inches or 88.9 mm) Width: 17.25 inches (438.15 mm) Depth: 10 inches (254 mm) Weight: 8 kg (17.64 lbs) empty, 11 kg (24.25 lbs)
  • Page 22 Technical Specifications Table Table 4-1 SCOPIA 400 Chassis Technical Specifications (continued) Board LED Indicators Front panel ETHERNET: Link Connection Speed LOAD (MCU only) CD (Gateways only) ALRM MC (MVP and MVP/M only) Rear panel PRI 1 or 2: (Gateway P20 SP)
  • Page 23 Technical Specifications Table Table 4-1 SCOPIA 400 Chassis Technical Specifications (continued) Rear panel 2 x ISDN E1/T1 PRI port: (Gateway P20 SP T1 mode Gateway [gw-P25/M SP]) Channels: 23B + 1D Clock rate: 1.544 Mbps Framing: F4, F12, ESF no CRC, ESF, F72 Encoding: NRZ, AMI-B7, B8ZS Line impedance: 100Ω...
  • Page 24 Technical Specifications Table Table 4-1 SCOPIA 400 Chassis Technical Specifications (continued) Ventilation Fans 2 fan units Brushless 12V DC motor Locked rotor detection Polarity protection Auto-restart capability SCOPIA 400 Platform Guide...
  • Page 25: Safety

    To reduce the risk of damaging power surges, recommends RADVISION installing an AC surge arrestor in the AC outlet from which the SCOPIA 400 platform is powered. Changes or modifications to the device that are not approved by the Warning party responsible for compliance could void the user’s authority to operate the...
  • Page 26: Grounding

    Electrical Safety The power cable of the SCOPIA 400 platform should only be connected to a ROUNDING power outlet that has a protective earth contact. Do not use an extension cord that does not have a protective conductor (ground). The SCOPIA 400 chassis can become dangerous if you interrupt any of the protective conductors (grounding) or disconnect any of the protective earth terminals.
  • Page 27: Esd Procedures

    ESD Procedures ESD P ROCEDURES To prevent damage to element boards by random electrostatic RADVISION discharge (ESD), the use of wrist straps is highly recommended. Safety...
  • Page 28: Sicherheit

    ICHERHEIT vorgenommen werden. empfiehlt zur Minderung des Risikos von Stromstößen die RADVISION Installation eines Stromableiters in der Stromquelle, aus der die SCOPIA 400 gespeist wird. Das Stromkabel der SCOPIA 400/1000 Plattform darf nur an Stromquellen RDUNG angeschlossen werden, die einen sch?tzenden Erdkontakt aufweisen. Keine Verlängerungsschnur verwenden, die keinen Schutzleiter (Erdung) aufweisen.
  • Page 29: Esd-Verfahren

    ESD-Verfahren ESD-V ERFAHREN Zur Vermeidung von Beschädigungen der Einsatzelemente durch RADVISION zufällige elektrostatische Entladungen (ESD) wird die Verwendung von Schlaufen sehr empfohlen. ARNHINWEISE Änderungen oder Modifikationen, die von der für die Einhaltung verantwortlichen Partei nicht ausdrücklich genehmigt sind, können die Erlaubnis zur Nutzung des Geräts durch den Benutzer unwirksam machen.
  • Page 30: Seguridad

    Desconecte el chasis SCOPIA 400 de la fuente de suministro de energia antes de OLTAGE remover la tapa. Evite hacer ajustes, mantenimiento o reparar un chasis abierto y encendido.
  • Page 31: Abastecimiento De Electricidad

    ROCEDIMIENTOS Para prevenir daño a las tarjetas elementos de por descargas RADVISION electrostáticas aleatorias (ESD), el uso de bandas conductoras para descarga en la muñeca de los operadores en el área es altamente recomendado. Seguridad...
  • Page 32: Securite

    Securite Electrique ECURITE Cette section décrit les procédures et les exigences en matière de sécurité concernant la mise en exploitation de la SCOPIA 400 platform. Les sujets suivants y sont en particulier abordés: Sécurité Électrique Prevention des Décharges Électrostatiques ECURITE Afin de prévenir tout risque d’électrocution ou de détérioration de la...
  • Page 33: Haute Tension

    En Suède et en Finlande, l’installation ne doit se faire que dans des Attention zones à accès contrôlé. Débranchez le SCOPIA 400 chassis de la prise électrique avant d’enlever le AUTE ENSION couvercle. Évitez toute intervention, opération d’entretien ou réparation sur un châssis ouvert sous tension.
  • Page 34 Prevention des Decharges Electrostatiques SCOPIA 400 Platform Guide...
  • Page 35: Compliance And Certifications

    SCOPIA 400 platform, including the following topics: Safety Compliance Telecom Environmental Compliance AFETY This section lists the safety standards supported by the SCOPIA 400 platform. OMPLIANCE UL 60950: 2000 CAN/CSA C22.2 No. 60950-00 GS Approval (EN 60950: 2000) EN 60950: 2000...
  • Page 36: Emc

    This section lists the EMC compliance for the SCOPIA 400 platform. FCC Part 15, Subpart B, Class A ICES-003 EN 55022: 1998, Class A EN 55024: 1998 EN 61000-3-2: 1995, Amendment A14: 2000 EN 61000-3-3: 1995 IEC 61000-4-2: 1995 IEC 61000-4-3: 1995...
  • Page 37: Telecom

    It is designed to be connected to a compatible modular jack that is also compliant. See Installation Instructions for details. If the SCOPIA 400 platform equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required.
  • Page 38: Canadian Department Of Communications Notice

    If trouble is experienced with the SCOPIA 400 platform equipment, for repairs or warranty information please contact Inc. customer support at +1.201.529.4300 for RADVISION information on service or repairs.
  • Page 39: Environmental Compliance

    Users should not attempt to make such connections themselves, but should contact the appropriate E1/T1/PRI electric inspection authority, or appropriate E1/T1/PRI electrician. NVIRONMENTAL complies with the following EU Directives: RADVISION OMPLIANCE Restrictions on the Use of Hazardous Substances (RoHS) Directive 2002/95/EC Waste Electrical and Electronic Equipment (WEEE) Directive...

Table of Contents