Configuring Gateway Settings
C
IVR
ONFIGURING
S
ETTINGS
92
SCOPIA 400/1000 Gateway User Guide
Table 3-7
Disconnect Reasons (continued)
Number
H.323 Call Disconnect Reason
16
Call deflection has occurred.
17
Access denied.
18
The called party is not registered at the destination.
19
The calling party is not registered.
20
The connection failed and a new one should be made.
21
The called party has no H.245 capabilities.
22
Facility message sends conference list choice.
23
Request to establish H.245 connection.
24
An indication from an endpoint or a gatekeeper to send a new set of tokens
in the tokens and/or cryptoTokens field of the Facility message.
25
Indicates that the purpose of the message is to update feature set
information that was previously sent in the Facility message.
26
Indicates that the purpose of the message is to forward elements of another
message, if that message cannot be sent.
27
Indicates that the purpose of the message is to transport higher-layer
information.
In the IVR section of the Settings tab, you can configure the Gateway to route
calls using an Interactive Voice Response (IVR) system.
Procedure
In the Gateway interface, on the sidebar, click Gateway (if not already
1
selected).
Click the Settings tab.
2
3
Click the IVR button.