4.3.3 Test operation

Before starting actual operation, perform test operation to make sure that the machine operates normally.
Refer to section 4.3.1 for the power on and off methods of the servo amplifier.
Test operation of servo motor
alone in JOG operation of test
operation mode
Test operation of servo motor
alone by commands
Test operation with servo motor
and machine connected
In this step, confirm that the servo amplifier and servo motor
operate normally.
With the servo motor disconnected from the machine, use the
test operation mode and check whether the servo motor
correctly rotates at the slowest speed. Refer to section 6.9 for
the test operation mode.
In this step, confirm that the servo motor correctly rotates at the
slowest speed under the commands from the command device.
Make sure that the servo motor rotates in the following
procedure.
1) Switch on the Emergency stop (EMG) and Servo-on (SON).
When the servo amplifier is put in a servo-on status, the
Ready (RD) switches on.
2) Switch on the Forward rotation stroke end (LSP) or Reverse
rotation stroke end (LSN).
3) When the analog speed command (VC) is input from the
command device and the Forward rotation start (ST1) or
Reverse rotation start (ST2) is switched on, the servo motor
starts rotating. Give a low speed command at first and check
the rotation direction, etc. of the servo motor. If the servo
motor does not operate in the intended direction, check the
input signal.
In this step, connect the servo motor with the machine and
confirm that the machine operates normally under the
commands from the command device.
Make sure that the servo motor rotates in the following
procedure.
1) Switch on the Emergency stop (EMG) and Servo-on (SON).
When the servo amplifier is put in a servo-on status, the
Ready (RD) switches on.
2) Switch on the Forward rotation stroke end (LSP) or Reverse
rotation stroke end (LSN).
3) When the analog speed command (VC) is input from the
command device and the Forward rotation start (ST1) or
Reverse rotation start (ST2) is switched on, the servo motor
starts rotating. Give a low speed command at first and check
the operation direction, etc. of the machine. If the machine
does not operate in the intended direction, check the input
signal. In the status display, check for any problems of the
servo motor speed, load ratio, etc.
4) Then, check automatic operation with the program of the
command device.