3. SIGNALS AND WIRING
Device
Symbol
External torque
TL
limit selection
Internal
TL1
torque limit
selection
Forward rotation
ST1
start
Reverse rotation
ST2
start
Forward rotation
RS1
selection
Reverse rotation
RS2
selection
Connec-
tor pin
No.
CN1-18 Turn TL off to make Forward torque limit (parameter No. PA11) and
Reverse torque limit (parameter No. PA12) valid, or turn it on to
make Analog torque limit (TLA) valid.
For details, refer to section 3.6.1 (5).
When using this signal, make it usable by making the setting of
parameter No. PD03 to PD08, PD10 to PD12.
For details, refer to section 3.6.1 (5).
CN1-17
Used to start the servo motor in any of the following directions:
(Note) Input signals
ST2
ST1
0
CN1-18
0
1
1
Note. 0: off
1: on
If both ST1 and ST2 are switched on or off during operation, the
servo motor will be decelerated to a stop according to the parameter
No. PC02 setting and servo-locked.
When "
1 " is set in parameter No. PC23, the servo motor is not
servo-locked after deceleration to a stop.
CN1-18
Used to select any of the following servo motor torque generation
directions:
(Note) Input signals
RS2
RS1
0
CN1-17
0
1
1
Note. 0: off
1: on
Functions/Applications
Servo motor starting direction
0
Stop (servo lock)
1
CCW
0
CW
1
Stop (servo lock)
Torque generation direction
0
Torque is not generated.
Forward rotation in driving mode / reverse
1
rotation in regenerative mode
Reverse rotation in driving mode / forward
0
rotation in regenerative mode
1
Torque is not generated.
3 - 28
Control
I/O
mode
division
P
S
T
DI-1
DI-1
DI-1
DI-1