Mitsubishi Electric Melservo MR-J3-A Instruction Manual page 173

Servo amplifier
Table of Contents

Advertisement

5. PARAMETERS
No.
Symbol
PC11
SC7
Internal speed command 7
Used to set speed 7 of internal speed commands.
Internal speed limit 7
Used to set speed 7 of internal speed limits.
PC12
VCM
Analog speed command maximum speed
Used to set the speed at the maximum input voltage (10V) of the
analog speed command (VC).
Set "0" to select the rated speed of the servo motor connected.
The speed is as indicated below for motorless operation of test
operation.
Servo amplifier capacity [W]
100V class
200V class
400V class
Analog speed limit maximum speed
Used to set the speed at the maximum input voltage (10V) of the
analog speed limit (VLA).
Set "0" to select the rated speed of the servo motor connected.
PC13
TLC
Analog torque command maximum output
Used to set the output torque at the analog torque command
voltage (TC
torque is 100[%]. For example, set 50 to output (maximum torque
50/100) at the TC of 8V.
Name and Function
Servo motor speed [r/min]
100 to 400
100 to 750
1k to 37k
600 to 55k
8V) of 8V on the assumption that the maximum
Initial
Value
800
0
3000
2000
0
100.0
5 - 30
Setting
Control Mode
Unit
Range Position Speed Torque
r/min
0 to
instan-
taneous
permi-
ssible
speed
0
r/min
1
to
50000
0
r/min
1
to
50000
%
0
to
1000.0