14. ABSOLUTE POSITION DETECTION SYSTEM
(2) Sequence program example
(a) Conditions
1) Operation pattern
ABS data transfer is made as soon as the servo-on pushbutton is turned on. After that, positioning
operation is performed as shown below:
address
After the completion of ABS data transmission, JOG operation is possible using the JOG or JOG
pushbutton switch.
After the completion of ABS data transmission, dog type home position return is possible using the
home position return pushbutton switch.
2) Buffer memory assignment
For BFM#26 and later, refer to the FX
BMF No.
Upper 16
Lower 16
bits
-
#2
-
#5
-
#8
#10
-
-
#14
-
-
#18
#20
#22
#24
-
3) Instructions
When the servo-on pushbutton switch and the GND of the power supply are shorted, the ABS data is
transmitted when the servo amplifier power is turned ON, or at the leading edge of the RUN signal
after a PC reset operation (PC-RESET). The ABS data is also transmitted when an alarm is reset, or
when the emergency stop state is reset.
If check sum discrepancy is detected in the transmitted data, the ABS data transmission is retried up
to three times. If the check sum discrepancy is still detected after retrying, the ABS check sum error is
generated (Y12 ON).
The following time periods are measured and if the ON/OFF state does not change within the
specified time, the ABS communication error is generated (Y11 ON).
ON period of ABS transfer mode (Y1)
ON period of ABS request (Y2)
OFF period of ready to send the ABS data (X2).
3)
300000
Name and symbol
bits
#0
Pulse rate
#1
Feed rate
#3
Parameter
#4
Max. speed
#6
Bias speed
#7
JOG operation
#9
Home position return speed (high speed)
#11
Home position return speed (creep)
#12
Home position return zero-point signal count
#13
Home position address
#15
Acceleration/deceleration time
#16
Not usable
#17
Target address (I)
#19
Operation speed (I)
#21
Target address (II)
#23
Operation speed (II)
#25
Operation command
Home position
1)
0
2)
-1PG User's Manual.
2(N)
Vmax
Vbia
Vjog
V
V
HP
P(I)
V(I)
P(II)
V(II)
14 - 23
300000
Set value
A
2000
B
1000
H0000
Command unit: Pulses
100000PPS
0PPS
10000PPS
50000PPS
RT
1000PPS
CL
N
2 pulses
0
Ta
200ms
0
100000
0
10
H0000
Remark
Initial value: 10
Initial value: 100
Initial value: 10