Operation Example - Mitsubishi Electric Melservo MR-J3-A Instruction Manual

Servo amplifier
Table of Contents

Advertisement

6. DISPLAY AND OPERATION SECTIONS

6.6.2 Operation example

(1) Parameter of 5 or less digits
The following example shows the operation procedure performed after power-on to change the control
mode (Parameter No. PA01) into the speed control mode. Press "MODE" to switch to the basic setting
parameter screen.
To shift to the next parameter, press the "UP" or "DOWN" button.
When changing the parameter No. PA01 setting, change its set value, then switch power off once and
switch it on again to make the new value valid.
Press
MODE
four times. Select parameter No.8 with UP
The parameter number is displayed.
Press
UP
or
DOWN
to change the number.
Press
SET
twice.
The set value of the specified parameter number flickers.
Press
UP
twice.
During flickering, the set value can be changed.
Use
UP
or
DOWN
.
(
2: Speed control mode)
Press
SET
to enter.
6 - 11
or
DOWN.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents