(1) Combination and regenerative power
The power values in the table are resistor-generated powers and not rated powers.
Built-in
Servo amplifier
regenerative
resistor
MR-J3-10A (1)
MR-J3-20A (1)
10
MR-J3-40A (1)
10
MR-J3-60A
10
MR-J3-70A
20
MR-J3-100A
20
MR-J3-200A
100
MR-J3-350A
100
MR-J3-500A
130
MR-J3-700A
170
Built-in
Servo amplifier
regenerative
resistor
MR-J3-60A4
20
MR-J3-100A4
20
MR-J3-200A4
100
MR-J3-350A4
100
MR-J3-500A4
130
MR-J3-700A4
170
Servo amplifier
External regenerative
resistor (Accessory)
MR-J3-11KA
MR-J3-15KA
850 (1300)
MR-J3-22KA
850 (1300)
MR-J3-11KA4
MR-J3-15KA4
850 (1300)
MR-J3-22KA4
850 (1300)
Note 1. Always install a cooling fan.
2. Values in parentheses assume the installation of a cooling fan.
The specified combinations of regenerative options and servo amplifiers may only
be used. Otherwise, a fire may occur.
MR-RB032
MR-RB12
[40 ]
[40 ]
30
30
100
30
100
30
100
30
100
30
100
(Note 1)
MR-RB1H-4
MR-RB3M-4
[82 ]
[120 ]
100
100
MR-RB5E
[6 ]
500 (800)
500 (800)
500 (800)
Regenerative power[W]
MR-RB30
MR-RB31
[13 ]
[6.7 ]
300
300
Regenerative power[W]
(Note 1)
(Note 1)
MR-RB3G-4
MR-RB5G-4
[47 ]
300
300
300
300
(Note 2) Regenerative power[W]
MR-RB9P
MR-RB9F
[4.5 ]
[3 ]
850 (1300)
850 (1300)
12 - 22
(Note 1)
MR-RB32
MR-RB50
[40 ]
300
300
300
300
(Note 1)
MR-RB34-4
MR-RB54-4
[47 ]
[26 ]
500
500
300
300
MR-RB6B-4
MR-RB60-4
[20 ]
[12.5 ]
500 (800)
850 (1300)
(Note 1)
MR-MB51
[13 ]
[6.7 ]
500
500
500
500
(Note 1)
[26 ]
500
500
MR-RB6K-4
[10 ]
850 (1300)