7. SERVO CONFIGURATION SOFTWARE
7.7 Test operation
CAUTION
7.7.1 Jog operation
Hold down the "Forward" or "Reverse" button to rotate the servo motor. Release the "Forward" or
"Reverse" button to stop.
Click "Test" on the menu bar and choose "Jog" on the menu.
Clicking displays the following window.
Since this window shows the precaution for use of the MR-J2S-B, click the "OK" button.
The test operation mode is designed to confirm servo operation and not to confirm
machine operation. In this mode, do not use the servo motor with the machine.
Always use the servo motor alone.
If any operational fault has occurred, stop operation using the forced stop (EMG).
POINT
In the jog operation mode, do not rewrite data from the point table list
screen or the servo amplifier's front panel. Otherwise, the set values are
made invalid.
The servo motor will not operate if the forced stop (EMG), forward
rotation stroke end (LSP) and reverse rotation stroke end (LSN) are off.
Make automatic ON setting to turn on these devices or make device
setting to assign them as external input signals and turn on across these
signals and SG. (Refer to Section 7.6.)
7 - 12