Power Saving Commands - D-Link xStack DES-3528 Series Cli Reference Manual

Layer 2 managed stackable fast ethernet switch cli
Hide thumbs Also See for xStack DES-3528 Series:
Table of Contents

Advertisement

xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch CLI Reference Guide

Power Saving Commands

The Power Saving Commands in the Command Line Interface (CLI) are listed (along with the appropriate parameters)
in the following table.
Command
config power_saving
config power_saving
hibernation
config power_saving led
config power_saving port
config power_saving mode
show power_saving
config led state
show led
Each command is listed, in detail, in the following sections.
config power_saving
Purpose
Syntax
Description
Parameters
Restrictions
Example usage:
To configure power saving:
Parameters
{state [enable | disable] | length_detection [enable | disable]}
[[add | delete] time_range <range_name 32> | clear_time_range]
[[add | delete] time_range <range_name 32> | clear_time_range]
[<portlist> | all] [[add | delete] time_range <range_name 32> | clear_time_range]
{length_detection | link_detection | led | port | hibernation} [enable | disable]
{length_detection | link_detection | led | port | hibernation}
[enable | disable]
This command is used to configure the power saving for the system.
config power_saving {state [enable | disable] | length_detection [enable | disable]}
By default, the power saving mode is enabled and the length detection mode is enabled. The
power saving length detection function applies to the ports with copper media.
The power is saved by the following mechanisms. When the port has no link partner, the port
automatically turns off and wakes up once a second to send a single link pulse. When the
port is turned off, a simple receive energy-detect circuit is continuously monitoring energy on
the cable. At the moment when energy is detected, the port turns on fully per IEEE
specification requirements. The power saving function is performed while no link is detected
and it will not affect the port capabilities while it is link up.
When the port is link up, for shorter cable, the power consumption can be reduced by
lowering the signal amplitude since the signal attenuation is proportional to the cable length.
The port will adjust the power based on cable length and still maintain error free applications
from both sides of the link. This mechanism will only be supported when the hardware
supports the cable diagnostics function.
state - (Optional) Configure the power saving state to enable or disable. The default value is
enable.
enable - Enable the power saving feature.
disable - Disable the power saving feature.
length_detection - Configure the length detection state to enable or disable. The default
value is enable.
enable - Enable the length detection feature.
disable - Disable the length detection feature.
Only Administrator and Operator-level users can issue this command.