D-Link xStack DES-3528 Series Cli Reference Manual page 579

Layer 2 managed stackable fast ethernet switch cli
Hide thumbs Also See for xStack DES-3528 Series:
Table of Contents

Advertisement

xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch CLI Reference Guide
To configure DDM log state to enable:
DES-3528:admin#config ddm log enable
Command: config ddm log enable
Success.
DES-3528:admin#
To configure DDM trap state to enable:
DES-3528:admin#config ddm trap enable
Command: config ddm trap enable
Success.
DES-3528:admin#
config ddm ports
Purpose
The command is used to configure the DDM settings of the specified ports.
Syntax
config ddm ports [<portlist> | all] [[temperature_threshold {high_alarm <degrees> |
low_alarm <degrees> | high_warning <degrees> | low_warning <degrees>} |
voltage_threshold {high_alarm <voltage> | low_alarm <voltage> | high_warning
<voltage> | low_warning <voltage>} | bias_current_threshold {high_alarm
<milliampere> | low_alarm <milliampere> | high_warning <milliampere> | low_warning
<milliampere>} | tx_power_threshold {high_alarm <mw_or_dbm> | low_alarm
<mw_or_dbm> | high_warning <mw_or_dbm> | low_warning <mw_or_dbm>} |
rx_power_threshold {high_alarm <mw_or_dbm> | low_alarm <mw_or_dbm> |
high_warning <mw_or_dbm> | low_warning <mw_or_dbm>}] | {state [enable | disable]
| shutdown [alarm | warning | none]} | reload_threshold]
Description
The command is used to configure the DDM settings of the specified ports.
Parameters
<portlist> - Enter the range of ports to be configured here.
all - Specify that all the optic ports' operating parameters will be configured.
temperature_threshold - Specify the threshold of the optic module's temperature in
centigrade. At least one parameter shall be specified for this threshold.
high_alarm - (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<degrees> - Enter the high threshold alarm value used here.
low_alarm - (Optional) Specify the low threshold for the alarm. When the operating
parameter falls below this value, the action associated with the alarm is taken.
<degrees> - Enter the low threshold alarm value used here.
high_warning - (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<degrees> - Enter the high threshold warning value here.
low_warning - (Optional) Specify the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<degrees> - Enter the low threshold warning value here.
voltage_threshold - Specify the threshold of optic module's voltage.
high_alarm - (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<voltage> - Enter the high threshold alarm value used here.
low_alarm - (Optional) Specify the low threshold for the alarm. When the operating
parameter falls below this value, the action associated with the alarm is taken.
<voltage> - Enter the low threshold alarm value used here.
high_warning - (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<voltage> - Enter the high threshold warning value here.
579

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents