config temperature
Purpose
Syntax
Description
Parameters
Restrictions
Example usage:
To enable the warning temperature trap state:
DES-3528:admin#config temperature trap state enable
Command: config temperature trap state enable
Success.
DES-3528:admin#
To enable the warning temperature log state:
DES-3528:admin#config temperature log state enable
Command: config temperature log state enable
Success.
DES-3528:admin#
config temperature threshold
Purpose
Syntax
Description
Parameters
Restrictions
Example usage:
To configure a warming temperature threshold high of 80:
This command is used to configure the warning trap or log state of the system internal
temperature.
config temperature [trap | log] state [enable | disable]
This command is used to configure the warning trap or log state of the system internal
temperature.
trap - Specify to configure the warning temperature trap.
log - Specify to configure the warning temperature log.
state - Enable or disable either the trap or log state for a warning temperature event. The
default is enable.
enable - Enable either the trap or log state for a warning temperature event.
disable - Disable either the trap or log state for a warning temperature event.
Only Administrator and Operator-level users can issue this command.
This command is used to configure the warning temperature high threshold or low threshold.
config temperature threshold {high <temperature -500-500> | low <temperature -500-
500>}
When temperature is above the high threshold or below the low threshold, SW will send
alarm traps or keep the logs.
high - Specify the high threshold value. The high threshold must bigger than the low
threshold.
<temperature -500-500> - Specify the high threshold value. This value must be between -500
and 500.
low - Specify the low threshold value.
<temperature -500-500> - Specify the low threshold value. This value must be between -500
and 500.
Only Administrator and Operator-level users can issue this command.