configure alert

The configure alert command selects the alert messages to send by email.
Previously configured messages display as configured and can be cleared.
Use the -get option to display the list of alerts and to build a local list of system
alerts before using the –set option to configure the alerts. Use the -set option to
clear the list. An error appears if you issue the –set option while the list is empty.
Command arguments:
<CLI> configure alert [ -get | -set | -setgenericalerttemplate ]
-help option
Usage
[-get]
[-set]
[-setgenericalerttemplate] : Enables the user to create or replace an entry in alertTemplates
on
off
email
initiallymasked
type
severity
msg
Where:
v number - Defines the reference number of the alert displayed by using the -get
option.
Examples:
<CLI> configure alert -get
Current Machine Local Time: 04/08/2009 09:47:11 AM
Ref# Code EmailOn
State
---- ----- -------
1
0
2
2
3
3
4
4
5
100
6
101
7
102
8
103
9
104
: configure alert -[get | set [-email | -initiallymasked]
-on <RefNum RefNum...> -off <RefNum RefNum...>
| setgenericalerttemplate -code <genericAlertCode>
-type [persistent|ackable] -initiallymasked [on|off]
-email [on|off] -severity [critical|warning|info]
-msg "DesiredAlertStringInQuotes"]
: Displays the email and initiallymasked properties of alerts
currently defined in alertTemplates.
: Enables the user to set the email and initiallymasked attribute
for any email.
for generic alerts.
: Sets the attribute to 'on' for the alertCode specified by RefNum.
: Sets the attribute to 'off' for the alertCode specified by RefNum.
: When email attribute is set for an alert, an email is generated
every time that alert is created in the system.When this attribute
is set, email is only generated for future events and not for
existing alerts.
: When this attribute is set for an alert, initiallymasked LED is
lighted every time that alert is created in the system.When this
attribute is set, LED is lighted for future events and not for
existing alerts.
: Defines the type of alert for generic alert being specified.
: Defines the severity of alert for generic alert being specified.
: Defines the message for the generic alert. The string should be
specified within quotes for this command. The string is saved in
the alertTemplates without the quotes.
InitialMask AlertMsg
State
----------- --------
On
Unmasked TestAlert %s
Off
Masked Compatible drive enclosure %<EnclosureId> found
Off
Masked Drive enclosure %<EnclosureId> removed
Off
Masked Drive enclosure %<EnclosureId> firmware updated
On
Masked Controller firmware updated
Off
Masked Disorderly shutdown detected - System restored from battery
backup
On
Unmasked Controller in survivor mode - Redundant controller
%<ControllerId> is offline
Off
Masked New controller recognized
Off
Masked Replacement media tray %<BackplaneId> detected
Chapter 8. Using the RAID Controller command line interface
63

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BladeCenter S SAS RAID Controller Module and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF