5703 • 9703
5703
Drive drive_ID metadata version is incompatible with current controller firmware version
Explanation: Discovered drive contains incompatible metadata version.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail. Alert clears when one of the following events occurs:
v The drive is removed.
v The drive is assimilated.
v The controller reboots with compatible controller firmware.
Operator response: Assimilate or remove the drive, or update controller firmware.
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
5710
Redundant drive group group_ID missing spare
Explanation: This redundant group has no viable spare.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears when the drive group becomes degraded or has a viable spare.
Operator response: Configure a global spare drive for the group.
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
9700
Controller configuration error - error
Explanation: The configuration file cannot be processed due to a syntax error, duplicate attribute, or unexpected end
of file. Possible causes:
v A parameter file was manually edited.
v An incorrect parameter file was loaded.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when controller reboots.
Operator response: Perform the following steps:
1. Debug the configuration file.
2. Reboot the controller.
3. If the problem persists, perform a concurrent controller firmware update.
9703
Controller configuration error - error, errno error_number
Explanation: Configuration file cannot be processed due to system I/O errors. Possible causes:
v A parameter file was manually edited.
v An incorrect parameter file was loaded.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when controller reboots.
Operator response: Perform the following steps:
1. Correct the problem.
2. Reboot the controller.
3. If the problem persists, perform a concurrent controller firmware update.