IBM BladeCenter S SAS RAID Controller Module Installation And User Manual page 143

Sas raid controller module
Table of Contents

Advertisement

1301
Drive drive_ID failure detected - Previous drive status was unassigned
Explanation: Drive failure condition caused controller to fail an unassigned, foreign, or IM drive.
System action: Drive mount state is set to DISMOUNTED. By default, the SAS RAID Module system information
indicator is turned on and the operator is notified of this alert by e-mail. The alert clears when the drive is removed.
Operator response: Replace the failed drive (see "Replacing a failed drive" on page 167).
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
1303
Drive drive_ID reports predicted failure - Current drive status is [inuse|spare]
Explanation: PFA detected.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when the drive is removed.
Operator response: Replace the drive (see "Replacing a failed drive" on page 167).
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
1304
Drive drive_ID reports predicted failure - Current drive status is unassigned
Explanation: PFA detected.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
notified of this alert by e-mail. Alert clears when the drive is removed.
Operator response: Replace the drive (see "Replacing a failed drive" on page 167).
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
1305
Drive drive_ID failure detected - Primary disk port unusable, previous drive status was [inuse|spare]
Explanation: Drive failure process initiated on a drive because of unreliable connectivity on servicer drive port of
assigned drive. Possible causes:
v Unusable error threshold exceeded.
v Persistent logged out condition.
System action: If drive is redundant or spare, the drive is failed and alert 1300 is generated. By default, the SAS
RAID Module system information indicator is not turned on and the operator is notified of this alert by e-mail. Alert
clears when the drive is removed.
Operator response: Replace the failed drive (see "Replacing a failed drive" on page 167).
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
1307
Drive drive_ID error condition detected - Secondary disk port unusable, current drive status
[inuse|spare|unassigned]
Explanation: Drive failure process initiated on a drive because of unreliable connectivity on servicer drive port of
assigned drive. Possible causes:
v Unusable error threshold exceeded.
v Persistent logged out condition.
The drive is not failed or dismounted based on secondary port status.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when the drive is removed.
Operator response: Replace the drive (see "Replacing a failed drive" on page 167)..
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
Chapter 11. Troubleshooting and support
1301 • 1307
133

Advertisement

Table of Contents
loading

Table of Contents