0100 • 2100

Controller informational alerts

The alerts in this section are generated as controller state warning messages.
0100
Controller controller_ID firmware updated
Explanation: The controller firmware has been updated successfully.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
notified of this alert by e-mail. Alert clears automatically.
Operator response: None.
0103
New controller recognized
Explanation: A surviving controller generates this alert when a factory replacement controller is recognized in the
other slot.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response: Acknowledge to clear the alert immediately.
0104
Replacement media tray backplane_ID detected
Explanation: The controller generates this alert when a factory replacement media tray is installed and recognized.
The media tray contains the system identity information that is normally associated with the chassis or backplane.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response: Acknowledge to clear the alert immediately.
Controller ready for service controller_ID
2100
Explanation: A previously bound controller is ready for removal. Possible causes:
v Unrecoverable controller failure.
v Operator requested offline condition (part of the concurrent controller replacement procedure).
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. The controller fault light turns on, indicating "ready to remove" state. Alert clears if
controller is rebooted.
Operator response: Replace the controller.
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator. Masking the
alert does not prevent the controller fault light from illuminating.