Controller informational alert history log events

The alerts in this section are generated for logging controller status. These operator
never sees them as active alerts.
0101
Disorderly shutdown detected - System restored from battery backup
Explanation: The controller backup battery system allows for recovery of cached write data when power fails
unexpectedly. This alert indicates completion of the data recovery. It is generated for logging purposes only.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically.
Operator response: None.
ArtsTime new_time - previous value was old_time
0105
Explanation: The controller maintains a operator-settable time and date that is also synchronized when two
controllers bind. This time is used when creating alerts and controller log entries.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically.
Operator response: None.
0110
API requested controller_ID to shutdown and [power off|enter service mode]
Explanation: The controller supports several cases for shutting down from normal operation. This alert creates a log
indicating the type of shutdown requested, which controllers are being shut down, and the source of the shutdown
request.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically.
Operator response: None.
0111
BMC requested controller_ID to shutdown and power off
Explanation: The controller supports several cases for shutting down from normal operation. This alert creates a log
indicating the type of shutdown requested, which controllers are being shut down, and the source of the shutdown
request.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically.
Operator response: None.