IBM BladeCenter S SAS RAID Controller Module Installation And User Manual page 145

Sas raid controller module
Table of Contents

Advertisement

4301
Unmasked drive firmware level is unsupported
Explanation: A disk drive with an unsupported firmware level is detected by the controller.
System action: The controller will not configure the disk drive.
Operator response: Remove the disk drive with the unsupported firmware level, or upgrade the disk drive
firmware level.
4302
Drive drive_ID specifies one or more missing drives already determined to be missing from a
previously discovered drive group. This drive is a member of drive group group_ID, a RAID
raid_level group containing drive(s) drive_list.
Explanation: A drive group has been discovered that specifies one or more member drives that are missing from the
system and already described as members of a previously discovered drive group. The previously discovered drive
group need not be mounted to cause this alert.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
notified of this alert by e-mail. Alert clears when the affected drives are assimilated or removed from the system.
Operator response: Assimilate or remove the affected drives.
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
Drive drive_ID specifies a group whose identity conflicts with an existing group. This drive is a
4303
member of drive group group_ID, a RAID raid_level group containing drive(s) drive_list.
Explanation: A drive group is discovered whose GUID conflicts with an already recreated group. The previously
discovered group need not be mounted to cause this alert.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
notified of this alert by e-mail. Alert clears when the affected drives are assimilated or removed from the system.
Operator response: Assimilate or remove the affected drives.
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
Drive drive_ID cannot be mounted without exceeding controller resource limits. This drive is a
4304
member of drive group group_ID, a RAID raid_level group containg drive(s) drive_list.
Explanation: A drive group is discovered that, if mounted, would cause one or more controller resource limits to be
exceeded (max volumes, max hosts, max terabytes, etc.).
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
notified of this alert by e-mail. Alert clears when the affected drives are assimilated or removed from the system.
Operator response: Assimilate or remove the affected drives.
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
Chapter 11. Troubleshooting and support
4301 • 4304
135

Advertisement

Table of Contents
loading

Table of Contents