Replacing A Media Tray - IBM BladeCenter S SAS RAID Controller Module Installation And User Manual

Sas raid controller module
Table of Contents

Advertisement

10. Install each drive in the replacement DSM. Refer to your record of drive
11. Use the Advanced Management Module to power on each RAID Controller.
What to do next
If the problem is not resolved, collect the logs and contact IBM.

Replacing a media tray

Perform the following steps to non-concurrently replace the IBM BladeCenter S
chassis media tray with the SAS RAID Module feature installed.
Procedure
162
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
b. Slide the DSM out of the IBM BladeCenter S chassis.
9. Install the replacement DSM.
a. Slide the DSM into the storage module bay until it stops.
b. Close the release handles (rotate the top handle down and the bottom
handle up).
positions to ensure that you install each drive in the same position.
a. Slide the drive into the DSM storage module bay until it stops.
b. Close the release handles (rotate the top handle down and the bottom
handle up).
a. Log into the Advanced Management Module.
b. Click I/O Module Tasks > Admin/Power/Restart.
c. Select the check box next to Bay 3 and Bay 4.
d. Select Power On Module(s).
e. Click OK and wait until each RAID Controller are powered on. The word
On is displayed in the Pwr column.
1. View the SAS RAID Module Active Alert List and select the alerts associated
with the Media Tray resource. The alert details are at the bottom of the page.
2. Scroll down to the operator response and click Replace Media Tray.
3. Stop all host I/O applications and power off the host servers.
4. Use the Advanced Management Module to power off both SAS RAID
Modules.
a. Log into the Advanced Management Module.
b. Click I/O Module Tasks > Admin/Power/Restart.
c. Select the check box next to Bay 3 and Bay 4.
d. Select Power Off Module(s).
e. Click OK.
f. Wait until both SAS RAID Modules are powered off. The word Off is
displayed in the Pwr column.
5. Make a note of the current SAS RAID Module IP Settings, and any custom
passwords.
a. Click I/O Module Tasks > Configuration.
b. Click Bay 3 under I/O Module Configuration.
c. Make a note of the Current IP Configuration for SAS Switch Subsystem.
The values to note are:
v IP Address
v Subnet Mask

Advertisement

Table of Contents
loading

Table of Contents