9600 • 0702
9600
Controller unable to bind - Usable drives different than survivor controller
Explanation: Unable to rebind with survivor due to missing drives that survivor can see or more drives than the
survivor sees. Possible causes include drive or expander failures.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when the controller reboots and all drives are discovered properly.
Operator response: Repair drive connectivity.
9601
Controller reports RAID system unable to begin operations - Usable drives different in each
controller
Explanation: Two controllers booting up see different drives, and neither controller can see all of the same drives as
the other controller. Possible causes include drive or expander failures.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when controller reboots and all drives are discovered properly.
Operator response: Repair drive connectivity.

Controller configuration alerts

The alerts in this section are generated to inform the operator of problems related
to controller configuration.
0700
Controller controller_ID configuration script script_name execution complete
Explanation: System configuration script has completed with no errors.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response: Acknowledge to clear the alert immediately.
0701
Controller port port_ID IP address changed to IP_address
Explanation: Requested IP address applied.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response: Acknowledge to clear the alert immediately.
0702
Controller timestamp updated
Explanation: Other controller and backplane timestamps are in sync, but the timestamp for this controller does not
match.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically.
Operator response: None.