Disk Drive Informational Alerts - IBM BladeCenter S SAS RAID Controller Module Installation And User Manual

Sas raid controller module
Table of Contents

Advertisement

9200 • 0307
9200
Battery battery_ID firmware update failed
Explanation: When the system boots up or a battery is inserted, the controller checks the battery firmware level. If
the firmware does not match the expected version, the controller automatically performs a firmware update. This
alert indicates that a firmware mismatch was detected, but the battery firmware update failed.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears if the battery is removed or a firmware update is initiated.
Operator response: Acknowledge to clear the alert immediately. Initiate another firmware update by removing and
reinserting the battery. If multiple attempts to update the firmware are unsuccessful, replace the battery (see
"Replacing a Battery Backup Unit" on page 177).

Disk drive informational alerts

The alerts in this section are generated as disk drive state warning messages.
0300
Spare drive drive_ID reassigned
Explanation: Rebuild operation has been started on the drive group and the spare drive has been selected for
rebuild.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response: Acknowledge to clear the alert immediately.
0303
Spare drive drive_ID copyback complete
Explanation: The copyback operation has completed and the spare drive is now available.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response: Acknowledge to clear the alert immediately.
0304
Drive drive_ID position has been updated
Explanation: By default, the SAS RAID Module system information indicator is not turned on and
System action: the operator is not notified of this alert by e-mail. Alert clears automatically.
Operator response: None.
0307
Drive drive_ID firmware upgraded
Explanation: Drive firmware upgrade has completed successfully.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response: Acknowledge to clear the alert immediately.