<CLI>
Broadcast message from root Mon Mar 4 16:37:19 2013...
The system is going down for reboot NOW !!
Log in the CLI prompt again and confirm both controllers are in SERVICE
state.
<CLI> list controller
Current Machine Local Time: 03/04/2013 04:39:12 PM
_______________________________________________________________________
|
Ctlr#
|
Controller
|_____________|________________|____________________|_________|_________|
|
0 |
|
1 |
|_____________|________________|____________________|_________|_________|
4. Remove the 6-DSM from the chassis.
a. Open the release handles on the DSM (rotate the top handle up and the
bottom handle down) to disengage the DSM from the IBM BladeCenter S
chassis.
b. Slide the DSM out of the IBM BladeCenter S chassis.
5. Insert the replacement 12-DSM in the chassis.
a. Slide the DSM into the storage module bay until it stops.
b. Close the release handles (rotate the top handle down and the bottom
handle up).
6. Enter list enclosure and press Enter to list the firmware version of the DSM.
If the firmware level of the replacement DSM is not higher than or equal to
7.15, alert 5014 will generate to indicate that the DSM firmware versions are not
equivalent. To resolve this condition and clear the alert, perform a
non-concurrent system reboot or non-concurrent firmware update.
<CLI> list enclosure
Current Machine Local Time: 03/04/2013 05:05:24 PM
_____________________________________________________________________________
|
Encl#
|
Enclosure
|_____________|________________|_________________|________________|___________|
|
0 |
|
1 |
|
2 |
|_____________|________________|_________________|________________|___________|
7. Enter mountstate –getobject –enclosure and press Enter to list the mount
state of the DSMs. Ensure that each DSM is online.
<CLI> mountstate -getobject -enclosure
Current Machine Local Time: 03/04/2013 05:15:22 PM
_______________________________________________________
| Enclosure# |
|_____________|_______________________|_________________|
|
0|
|
1|
|
2|
|_____________|_______________________|_________________|
8. Enter list drive and press Enter to list the drive summary for each disk drive
configured in the storage pool. Ensure that the mount state of all disk drives
inside the replacement DSM are in the online state.
|
Status
Ctlr0|
Ctlr1|
|
Type
Encl0 |
Controller |
Encl1 |
DSM SFF |
Encl2 |
DSM SFF |
State
|
Online|
Online|
Online|
Chapter 11. Troubleshooting and support
| Ports | LUNs
SERVICE|
1|
SERVICE|
1|
|
Version
| Status
0107 |
7.15 |
7.15 |
Type
|
Controller|
DSM SFF|
DSM SFF|
|
--|
--|
|
Good |
Good |
Good |
159
Need help?
Do you have a question about the BladeCenter S SAS RAID Controller Module and is the answer not in the manual?