5720
Spare drive carrier tray_ID has been disqualified, drive carrier spare drives converted to global
spares
Explanation: A group is created such that an existing spare tray is no longer qualified as a spare tray.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail.
Operator response: Acknowledge to clear the alert immediately. Assign a new spare drive or tray if required.
Drive group group_ID has been mounted with indeterminate data loss
9401
Explanation: This alert is caused by either of the following events:
v With the "force disorderly mount" controller setting is enabled, a mount operation was performed on a drive group
that was not orderly dismounted.
v All drives in the group are from the same controller and were mounted regardless of automount setting and "force
disorderly mount" setting.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail.
Operator response: Acknowledge to clear the alert immediately.
Drive group group_ID was not orderly dismounted - Acknowledge to mount with indeterminate data
9403
loss
Explanation: With the "force disorderly mount" controller setting disabled, a mount operation was attempted on a
drive group that was not orderly dismounted.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when the affected drive group is removed.
Operator response: Acknowledge to clear the alert immediately. Remove the affected drive group.
9405
Drive group group_ID has been orderly dismounted due to enclosure enclosure_ID fault condition.
Explanation: Due to enclosure critical environmentals, a forced orderly dismount was performed.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail.
Operator response: Acknowledge to clear the alert immediately.
9406
Drive group group_ID missing during powerfail recovery has been disorderly dismounted
Explanation: With "Auto Ack Pending Non-Viable" enabled, a PFR drive group was not found during PFR drive
discovery.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail.
Operator response: Acknowledge to clear the alert immediately.
Chapter 11. Troubleshooting and support
5720 • 9406
143
Need help?
Do you have a question about the BladeCenter S SAS RAID Controller Module and is the answer not in the manual?