5405 • 5414
5405
Drive group group_ID has been degraded due to enclosure enclosure_ID fault condition. Drive(s)
drive_list removed from drive group.
Explanation: Forced orderly dismount due to enclosure critical environmentals caused one or more "dropped"
drives, but the group is still viable.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail.
Operator response: Acknowledge to clear the alert immediately.
Long-running task canceled prior to completion: task_info
5406
Explanation: Volume service permanently aborted.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response: Acknowledge to clear the alert immediately.
5410
Stale drive group conflicting group name group_ID1 has been renamed to group name group_ID2
Explanation: Group rename occurred during discovery.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response: Acknowledge to clear the alert immediately.
5413
Previously mounted drive group group_ID comprised of drives drive_list does not match current
controller ID and has been removed from mounted group list.
Explanation: MGL group found but does not match the ID of this controller on cold boot.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail.
Operator response: Acknowledge to clear the alert immediately.
5414
Drive group group_ID is offline due to one or more missing drives.
Explanation: This alert is generated when a group becomes non-viable due to one or more missing drives. This can
occur at system startup if the group cannot be mounted due to missing non-redundant drives, or during normal
operation if the group was previously mounted and connectivity to one or more non-redundant drives is lost.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail.
Operator response: Acknowledge to clear the alert immediately. Reinsert the missing drives.
Note: In the R1 release, you must reboot the system with the missing drives in place in order to return the group
and its associated volumes to the mounted viable state with mapped LUNs online and accessible.