IBM BladeCenter S SAS RAID Controller Module Installation And User Manual page 156

Sas raid controller module
Table of Contents

Advertisement

5500 • 9510
5500
Host-LUN mapping conflict while mounting drive group. Host:LUN LUN maps to Group:Volume
group_ID:volume_ID.
Explanation: LUN mapping conflict resolved during mount.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response: Acknowledge to clear the alert immediately.
AutoHost overlap during mount of group group_ID. Volume volume_ID included for AutoHost
5501
host_ID.
Explanation: Auto host overlap detected during mount.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response: Acknowledge to clear the alert immediately.
9503
Host-LUN mapping conflict during mount of group group_ID. Host host_ID has no available LUNs
for mapping volume volume_ID. Host LUN LUN mapping deleted.
Explanation: Unresolvable LUN conflict.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response: Acknowledge to clear the alert immediately. Reconfigure LUN mapping.
9504
Volume volume_ID dismounted with data in write cache
Explanation: A transition to non-viable state occurred or volume was disorderly dismounted and the volume had at
least one sector of unflushed dirty cache.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail.
Operator response: Acknowledge to clear the alert immediately.
9510
Drive group group_ID maximum bad blocks exceeded - Volume volume_ID deleted
Explanation: The Bad Block count for the drive group has exceeded the maximum value.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail. The volume is deleted.
Operator response: Acknowledge to clear the alert immediately.
146
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module

Advertisement

Table of Contents
loading