IBM BladeCenter S SAS RAID Controller Module Installation And User Manual page 146

Sas raid controller module
Table of Contents

Advertisement

4322 • 5303
4322
Drive carrier tray_ID contains one or more unreliable or unsupported drives and cannot be mounted.
Please remove drive(s) drive_list and reinsert.
Explanation: Cannot mount tray due to unreliable or unsupported drives
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when the tray is removed.
Operator response: Remove unsupported or unreliable drives from system.
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
5300
Drive drive_ID firmware update failed
Explanation: Attempted drive firmware update operation was unsuccessful.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail.
Operator response: Acknowledge to clear the alert immediately. Retry the firmware update.
5301
Surplus capacity of replacement drive drive_ID will not be utilized
Explanation: Drive in replacement tray has too much capacity.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Replacement drive detection treats this as a qualified replacement drive and
automatically uses the spare. Alert clears automatically after 120 seconds.
Operator response: Acknowledge to clear the alert immediately.
Drive drive_ID cannot be used as a replacement.
5302
Explanation: Replacement drive is not qualified. This alert indicates that replacement drive detection has been
disabled for this group.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response: Acknowledge to clear the alert immediately. Assign a replacement spare drive manually.
5303
No drives discovered
Explanation: No drives were discovered during system boot-up. RAID Zero Step Setup is disabled.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears automatically when at least one drive is discovered.
Operator response: Acknowledge to clear the alert immediately.
136