5322
Drive carrier tray_ID is not qualified as a replacment. No spare tray assignment will be performed.
Explanation: Replacement tray is not qualified. This alert indicates that replacement drive detection has been
disabled for this group.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response: Acknowledge to clear the alert immediately. Assign a replacement spare drive manually.
RAID system down - Unsupported drive drive_ID detected
9300
Explanation: The system entered service mode because unsupported drives were detected on boot-up.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail. Alert clears when the unsupported drive is removed.
Operator response: Remove the unsupported drive.
9302
Drive drive_ID not accessible, please restore connectivity or acknowledge drive group group_ID
disorderly dismount with potential indeterminate data loss.
Explanation: The specified drive has no usable paths and is contributing to the specified mounted drive group not
being viable.
Note: If this condition is detected in power fail recovery and Auto Ack Pending Non-Viable is enabled, alert 9406 is
generated for the group and this alert is not generated for each missing drive group member drive.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail. Alert clears when one of the following events occurs:
v The specified drive is discovered in the system. (It might not be usable by the group.)
v Enough drives are discovered to make group viable (not including this drive).
v The drive group is deleted.
v One or more drive group members are failed as unreliable such that the group cannot become viable even if this
drive is reconnected.
Operator response: Acknowledge to clear the alert immediately. Restore the missing drive.
9303
Global spare drive drive_ID has been orderly dismounted due to enclosure enclosure_ID fault
condition.
Explanation: Forced orderly dismount due to enclosure critical environmentals.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response: Acknowledge to clear the alert immediately.