Volume Alerts - IBM BladeCenter S SAS RAID Controller Module Installation And User Manual

Sas raid controller module
Table of Contents

Advertisement

9412
Drive group group_ID volume migration in progress and destination group is missing. Volumes not
completely migrated to destination have been deleted.
Explanation: Volume migrate was suspended or interrupted, and the destination group is not available at system
reboot time.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail.
Operator response: Acknowledge to clear the alert immediately.
Drive group group_ID encountered indeterminate data loss
9413
Explanation: The controller was running with write cache disabled due to user setting (batteryless mode enabled)
and power was lost. On the next boot this RAID 5/6 group was marked uninitialized, but became degraded before
the init completed.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail.
Operator response: Acknowledge to clear the alert immediately.

Volume alerts

The alerts in this section are generated to inform the operator of changes in
volume status.
0500
Volume volume_ID unrecoverable media error - One or more bad blocks created in LBA range LBA1
to LBA2
Explanation: Due to unrecoverable media errors, bad blocks have been created on a volume within the reported
LBA range.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically.
Operator response: Rewrite the affected volume LBAs if possible.
0510
Volume volume_ID mounted and mapped to host-host_ID
Explanation: Stale volume mounted.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response: Acknowledge to clear the alert immediately.
3500
Volume volume_ID data redundancy error corrected
Explanation: Redundancy scan found and corrected an incoherency in the parity data for the volume.
System action: By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail.
Operator response: Acknowledge to clear the alert immediately.