IBM BladeCenter S SAS RAID Controller Module Installation And User Manual page 182

Sas raid controller module
Table of Contents

Advertisement

12. Remove the DSM from the chassis.
13. Record the slot position of each disk drive, then remove each disk drive from
14. Enter alert –get and press Enter to query the active alert list. Ensure alert
15. Insert each disk drive in the same slot position of the replacement DSM. You
16. Insert the replacement DSM in the chassis.
17. Enter alert –get and press Enter to query the active alert list. Ensure alert
18. Enter list enclosure and press Enter to list the firmware version of the DSM.
172
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
ONV/OFV/SV= Online Viable/Offline Viable/Service Viable
ONN=Online Non-viable/Pending Non-Viable; one or more drives are missing in this
pool.
The pool state changes to ONV if missing drive(s) comes back to the pool.
The pool state changes to OFN if the user acknowledges the alert.
a. Open the release handles on the DSM (rotate the top handle up and the
bottom handle down) to disengage the DSM from the IBM BladeCenter S
chassis.
b. Slide the DSM out of the IBM BladeCenter S chassis.
the DSM.
a. Open the release handle on the disk drive (rotate the handle up) to
disengage the hard disk drive from the DSM.
b. Slide the hard disk drive out of the DSM.
0003 was generated for the DSM that was removed from the chassis.
<CLI> alert -get
Current Machine Local Time: 09/15/2009 02:20:38 PM
Existing Alerts :
_________________________________________________________________________________________
|AlertCode| Id | Time
|========================================================================================|
| 3
| 22 | 20090915141947 | 0
|----------------------------------------------------------------------------------------|
| Msg: Drive enclosure 1 removed
|========================================================================================|
do not need to place each disk drive back in the same slot position of the
replacement DSM, however, it is a good practice to do so.
a. Slide the drive into the DSM storage module bay until it stops.
b. Close the release handles (rotate the top handle down and the bottom
handle up).
a. Slide the DSM into the storage module bay until it stops.
b. Close the release handles (rotate the top handle down and the bottom
handle up).
0002 was generated for inserting the replacement DSM in the chassis.
<CLI> alert -get
Current Machine Local Time: 09/15/2009 02:21:53 PM
Existing Alerts :
_________________________________________________________________________________________
|AlertCode| Id | Time
|========================================================================================|
| 2
| 42 | 20090915142137 | 0
|----------------------------------------------------------------------------------------|
| Msg: Compatible drive enclosure 1 found
|========================================================================================|
If the firmware level of the replacement DSM is not the same as the previous
DSM, alert 5014 will generate to indicate that the DSM firmware versions are
not equivalent. To resolve this condition and clear the alert, perform a
non-concurrent system reboot or non-concurrent firmware update.
| SlotID | Severity |WWN
| Info
|5005076b0741417f| 1
| SlotID | Severity |WWN
| Info
|5005076b0741417f| 1
| Ackable |MaskState|
| Masked |
|
| Ackable |MaskState|
| Masked |
|

Advertisement